Product View
EVE A41-V2.1 116Ah prismatic LFP cell.
Browse batteries and cells stocked in Europe.
Explore EU Stock →Browse batteries and cells stocked in the United States.
Explore USA Stock →Your shopping cart is empty!






| Lifepo4 | |
| Model | A41-116Ah |
| Version | Grade A+(HSEV) |
| Real Capacity | 120-125Ah |
| Nominal Voltage | 3.2V |
| Voltage range | 2.5V-3.65V |
| Max Discharge Current | 3C |
| Cycling Performance | DOD 70%; 3500 times DOD 80%; 2500 times |
| Size | 119*149*52mm |
| Weight | 1.98kg |
| Initial internal resistance | ≤ 0.8 mΩ |
| Terminal | Laser welding M6 stud |

EVE LITHIUM IRON PHOSPHATE CELL
3.22V High-Performance Prismatic LFP Battery Cell
A compact prismatic lithium iron phosphate cell designed for battery pack integration, energy storage projects and custom LiFePO4 battery builds. Refer to the official cell specification and follow the required BMS and operating limits.
| Cell Model | A41-V2.1 |
|---|---|
| Battery Chemistry | LiFePO4 (LFP) |
| Nominal Capacity | 116Ah |
| Nominal Voltage | 3.22V |
| Nominal Energy | 373.5Wh |
| AC Internal Resistance (Initial) | ≤ 0.35mΩ |
| DC Internal Resistance (Initial) | ≤ 0.8mΩ |
| Cell Weight | 1,985g ± 30g |
| Operating Voltage (0°C to 60°C) | 2.5–3.65V |
|---|---|
| Operating Voltage (−30°C to 0°C) | 2.0–3.65V |
| Standard Charge Current | 1/3C |
| Standard Discharge Current | 1/3C |
| Max. Continuous Charge Current | 3C (25–45°C) |
| Max. Pulse Discharge Current | 10C, 5 seconds at 25°C |
| Charge Temperature | −20°C to 55°C |
| Discharge Temperature | −30°C to 60°C |
Lithium iron phosphate cell in an aluminum prismatic case.
Up to 3C maximum continuous charging current under the specified 25–45°C condition.
Initial AC resistance ≤0.35mΩ and initial DC resistance ≤0.8mΩ under the specification's test conditions.
The specification lists overcharge, over-discharge, external short circuit, heating, temperature cycling, crush and acupuncture tests.
Approximate overall dimensions: 148.6 × 52.3 × 119.0mm, including terminals and insulation film.
Use a properly designed BMS to monitor cell voltage, temperature and operating conditions.

EVE A41-V2.1 116Ah prismatic LFP cell.

Reference drawing and overall cell dimensions.

Busbars, nuts and insulation boards

8pcs per box. The boxes are filled with high-density impact-resistant foam.
The A41-V2.1 cell can be evaluated for custom battery pack designs. The final pack configuration, usable energy, current capability and system performance depend on series/parallel configuration, BMS settings, thermal design and application conditions.
Follow the manufacturer's product specification for handling, charging, storage and transportation.
Storage: The specification recommends storage at 15–25% SOC, 0–25°C and relative humidity ≤60%. For storage at 0–25°C, periodic recharge is recommended every 6 months using the specified charge/discharge method before returning the cell to storage SOC.
Shipping: The specification states a shipping SOC of 15–25%. Protect cells from severe vibration, impact, extrusion, direct sunlight and rain.
Safety: Prevent over-discharge and maintain cell voltage above 2.5V during normal use. Never reverse-charge, short-circuit, immerse in water, expose to fire or high heat, or mechanically damage the cell. Stop using the cell if abnormal heat, odor, discoloration or deformation occurs.
Note: Cell-level test results do not replace system-level validation, pack certification or the safety design of the completed battery system.
Contact DOCAN ENERGY for product availability, order quantity, shipping options and technical documentation.
Contact DOCAN ENERGY